Clinical outcomes and predictors of restenosis in patients with femoropopliteal artery disease treated using polymer-coated paclitaxel-eluting stents or drug-coated balloons

Heart Vessels. 2022 Apr;37(4):555-566. doi: 10.1007/s00380-021-01941-9. Epub 2021 Sep 22.

Abstract

Both polymer-coated paclitaxel-eluting stents (PC-PESs) and drug-coated balloons (DCBs) are used in conjunction with endovascular therapy (EVT) for the treatment of peripheral artery disease (PAD). We aimed to identify the risk factors for the loss of patency following the use of PC-PES and DCB in a real clinical setting. We assessed the multi-center registry data of 151 lesions from 151 patients who underwent EVT for symptomatic PAD in the superficial femoral and proximal popliteal arteries using PC-PES or DCB. One-year primary patency (PP) and clinically driven target lesion revascularization (CD-TLR) were evaluated using Kaplan-Meier analysis. The predictive risk factors for 1-year outcomes were analyzed using the random survival forest method. PC-PES and DCB were used in 65 (43.0%) and 86 (57.0%) cases, respectively. There were no significant differences in 1-year PP or freedom from CD-TLR between PC-PES and DCB. PP occurred in 85.4% and 80.2% of cases in the PC-PES and DCB groups, respectively (log-rank p = 0.65), while freedom from CD-TLR was noted in 92.7% and 94.1% of cases in the PC-PES and DCB groups, respectively (log-rank p = 0.73). In order of importance, a Clinical Frailty Scale score ≥ 6, female sex, lower proximal vessel diameter, lower body mass index, and younger and older age were identified as predictive risk factors of restenosis in the PC-PES group. Peripheral artery calcification scoring system grade of ≥ 2, post-dissection pattern ≥ D, lower proximal and distal vessel diameter, and lesion length ≥ 100 mm were identified as predictive risk factors of restenosis, in order of importance, in the DCB group. Both PC-PES and DCB were associated with favorable clinical outcomes within 1 year in patients with femoropopliteal artery disease. Furthermore, several factors that could predict restenosis within 1 year following the use of each device were detected.

Keywords: Drug-coated balloon; Endovascular therapy; Peripheral artery disease; Polymer-coated paclitaxel-eluting stent; Predictor; Restenosis.

MeSH terms

  • Angioplasty, Balloon* / adverse effects
  • Coated Materials, Biocompatible
  • Drug-Eluting Stents*
  • Female
  • Femoral Artery
  • Humans
  • Paclitaxel / pharmacology
  • Peripheral Arterial Disease* / diagnosis
  • Peripheral Arterial Disease* / therapy
  • Polymers
  • Popliteal Artery / diagnostic imaging
  • Stents
  • Time Factors
  • Treatment Outcome
  • Vascular Patency

Substances

  • Coated Materials, Biocompatible
  • Polymers