Purpose: Higher energy (>6 MV) photons reduce dose inhomogeneity with breast tangent beams, thereby reducing late breast toxicity, but skin and superficial tissue sparing by higher energy beams raises concerns about local recurrence (LR) risk. This study aimed to determine whether beam energy and surgical bed-to-skin distance affect LR.
Methods and materials: This population-based study included newly diagnosed invasive breast cancers without skin involvement (pT1-4a, any-N, M0) treated with breast-conserving surgery and adjuvant whole breast radiation therapy without bolus or beam spoilers. The primary endpoint was the cumulative incidence of LR (CILR). Multivariable analysis (MVA) included mean beam energy, age, T-stage, nodal status, overall stage, lymphovascular invasion (LVI), grade, margin status, extensive intraductal component (EIC), breast cancer subtype, hormone therapy, and chemotherapy. In a subgroup with contoured surgical beds, another MVA included surgical bed-to-skin distance.
Results: The cohort consisted of 10,083 women treated from 2002 to 2011: 327 with 4 MV, 6006 with 6 MV, 2083 with >6 to 10 MV, and 1667 with >10 MV tangents. The median follow-up time was 11.1 years. The 10-year CILR was 3.1% (95% confidence interval [CI], 1.6-5.4) with 4 MV, 2.8% (2.4-3.3) with 6 MV, 4.2% (3.4-5.3) with >6 to 10 MV, and 2.6% (1.9-3.5) with >10 MV. On MVA of the entire cohort, LR risk was increased with positive margins, LVI, EIC, and lack of hormone therapy, but was not associated with beam energy (hazard ratio [HR], 1.01; 95% CI, 0.96-1.05; P = .8). On MVA of 3359 patients with contoured surgical beds, LR risk was not associated with surgical bed-to-skin distance (HR, 1.00; 95% CI, 0.99-1.02; P = .8).
Conclusions: Use of higher breast tangent beam energies is not associated with increased risk of LR, including in cases with surgical beds that are close to the skin.
Copyright © 2021 Elsevier Inc. All rights reserved.