Abstract

The goal of this article is to aid the orthopedic surgeon in determining whether an intra-medullary (IM) device for fixation of a distal tibia fracture is feasible. Using Computed Tomography (CT) scans of the fracture, this review demonstrates a simple way to determine whether two or even three distal interlocking screws are achievable in stable bone. Additionally, this paper offers a summary chart of commonly used tibial nails which can be used for planning purposes. Finally, a clinical summary of very distal tibial shaft fractures treated with IM fixation is provided.

Keywords: Distal tibia; Surgical planning; Tibia fracture; Tibial nail.

Publication types

  • Review

MeSH terms

  • Bone Nails
  • Fracture Fixation, Intramedullary*
  • Humans
  • Nails
  • Tibia
  • Tibial Fractures* / diagnostic imaging
  • Tibial Fractures* / surgery