Background: Patients with concomitant anemia and congestive heart failure have poor outcomes. The prevalence and clinical risk of anemia in patients receiving durable left ventricular assist devices (LVAD) remain unknown.
Methods: We retrospectively analyzed patients who underwent LVAD implantation between 2014 and 2018. The association between hemoglobin level at the time of index discharge and the one-year composite endpoint of heart failure readmissions or hemocompatibility-related adverse events was investigated.
Results: A total of 168 patients (57 [48, 66] years old, 123 males) were included and stratified into a classification of anemia (hemoglobin <9.7 g/dl, N = 99) or non-anemia (N = 69). The anemia group had a higher one-year incidence of the composite endpoint (56% vs 36%, p = .013) with an adjusted hazard ratio of 1.83 (95% confidence interval 1.08-2.82). Patients with anemia also experienced suboptimal bi-ventricular unloading.
Conclusions: Anemia was prevalent in LVAD patients and associated with a greater risk of heart failure and hemocompatibility-related adverse events. The optimal threshold for therapeutic intervention in response to post-LVAD anemia needs further investigation.
Keywords: heart failure; hemocompatibility; hemodynamics; mechanical circulatory support.
© 2022 International Center for Artificial Organ and Transplantation (ICAOT) and Wiley Periodicals LLC.