Study objective: The aim of this study was to evaluate the performance of indocyanine green (ICG) compared to that of the gold standard 99mtechnetium (99mTc-nanocolloids) in detecting sentinel lymph nodes (SLN) in early vulvar cancer.
Material and methods: A single-center retrospective cohort study comparing SLN detection by 99mTc-nanocolloids and ICG was performed in patients presenting early vulvar cancer (T1/2), with clinically negative nodes. All SLN showing a radioactive and/or fluorescent signal were resected. The primary endpoints were the sensitivity, positive predictive value (PPV) and false negative (FN) rate of ICG in detecting SLN compared to 99mTc-nanocolloids.
Results: Thirty patients were included and 99 SLN were identified in 43 groins. Compared to 99mTc-nanocolloids, ICG had a sensitivity of 80.8% (95% CI [72.6; 88.6%]), a PPV of 96.2% (95% CI [91.8; 100%]) and a FN rate of 19.1% in detecting SLN. Seventeen (17.1%) infiltrated (positive) SLN were identified out of the 99 SLN detected. Compared to 99mTc-nanocolloids, ICG showed a sensitivity of 82.3% (95% CI [73.1; 91.5%]), a PPV of 100% and a FN rate of 17.6% (3/17) in detecting infiltrated SLN.
Conclusion: Despite its many advantages, ICG cannot be used as the sole tracer for the detection of SLN in early vulvar cancer and should be employed in conjunction with 99mTc-nanocolloids.
Keywords: colorimetric; intraoperative detection; radioactive; sentinel lymph node; vulvar cancer.