Background: COVID-19 has caused the deferral of millions of elective procedures, likely resulting in a backlog of cases. We estimate the number of postponed surgical aortic valve replacement (sAVR) and transcatheter aortic valve replacement (TAVR) procedures during the first two waves of the COVID-19 pandemic in Germany.
Methods: Using German national records, all isolated TAVR and sAVR procedures between 2007 and 2020 were identified. Using weekly TAVR and sAVR procedures between 2017 and 2019, we created a forecast for 2020 and compared it with the observed number of procedures in 2020.
Results: In Germany, a total of 225,398 isolated sAVR and 159,638 isolated TAVR procedures were conducted between 2007 and 2020 that were included in our analysis. The reduction in all AVR procedures (sAVR and TAVR) for the entire year 2020 was 19.07% (95%CI: 15.19-22.95%). During the first wave of the pandemic (week 12-21), the mean weekly reduction was 32.06% (23.44-40.68%) and during the second wave of the pandemic (week 41-52), the mean weekly reduction was 25.58% (14.19-36.97%). The number of sAVR procedures decreased more than the number of TAVR procedures (24.63% vs. 16.42% for the entire year 2020).
Conclusion: The first year of the COVID-19 pandemic saw a substantial postponing of AVR procedures in Germany. Postponing was higher for sAVR than for TAVR procedures and less pronounced during the second wave of the COVID-19 pandemic.
Keywords: Covid-19; TAVI; sAVR.
© 2023. The Author(s).