Practice of neuromonitoring in open and endovascular thoracoabdominal aortic repair-an international expert-based modified Delphi consensus study

Eur J Cardiothorac Surg. 2023 Jun 1;63(6):ezad198. doi: 10.1093/ejcts/ezad198.

Abstract

Objectives: Spinal cord injury is detrimental for patients undergoing open or endovascular thoracoabdominal aortic aneurysm (TAAA) repair. The aim of this survey and of the modified Delphi consensus was to gather information on current practices and standards in neuroprotection in patients undergoing open and endovascular TAAA.

Methods: The Aortic Association conducted an international online survey on neuromonitoring in open and endovascular TAAA repair. In a first round an expert panel put together a survey on different aspects of neuromonitoring. Based on the answers from the first round of the survey, 18 Delphi consensus questions were formulated.

Results: A total of 56 physicians completed the survey. Of these, 45 perform open and endovascular TAAA repair, 3 do open TAAA repair and 8 do endovascular TAAA repair. At least 1 neuromonitoring or protection modality is utilized during open TAAA surgery. Cerebrospinal fluid (CSF) drainage was used in 97.9%, near infrared spectroscopy in 70.8% and motor evoked potentials or somatosensory evoked potentials in 60.4%. Three of 53 centres do not utilize any form of neuromonitoring or protection during endovascular TAAA repair: 92.5% use CSF drainage; 35.8%, cerebral or paravertebral near infrared spectroscopy; and 24.5% motor evoked potentials or somatosensory evoked potentials. The utilization of CSF drainage and neuromonitoring varies depending on the extent of the TAAA repair.

Conclusions: The results of this survey and of the Delphi consensus show that there is broad consensus on the importance of protecting the spinal cord to avoid spinal cord injury in patients undergoing open TAAA repair. Those measures are less frequently utilized in patients undergoing endovascular TAAA repair but should be considered, especially in patients who require extensive coverage of the thoracoabdominal aorta.

MeSH terms

  • Aortic Aneurysm, Thoracic* / surgery
  • Blood Vessel Prosthesis Implantation* / adverse effects
  • Delphi Technique
  • Endovascular Procedures* / adverse effects
  • Humans
  • Retrospective Studies
  • Risk Factors
  • Spinal Cord Injuries*
  • Spinal Cord Ischemia* / etiology
  • Spinal Cord Ischemia* / prevention & control
  • Spinal Cord Ischemia* / surgery
  • Treatment Outcome