Purpose: Medical imaging has become increasingly important in diagnosing and treating oncological patients, particularly in radiotherapy. Recent advances in synthetic computed tomography (sCT) generation have increased interest in public challenges to provide data and evaluation metrics for comparing different approaches openly. This paper describes a dataset of brain and pelvis computed tomography (CT) images with rigidly registered cone-beam CT (CBCT) and magnetic resonance imaging (MRI) images to facilitate the development and evaluation of sCT generation for radiotherapy planning.
Acquisition and validation methods: The dataset consists of CT, CBCT, and MRI of 540 brains and 540 pelvic radiotherapy patients from three Dutch university medical centers. Subjects' ages ranged from 3 to 93 years, with a mean age of 60. Various scanner models and acquisition settings were used across patients from the three data-providing centers. Details are available in a comma separated value files provided with the datasets.
Data format and usage notes: The data is available on Zenodo (https://doi.org/10.5281/zenodo.7260704, https://doi.org/10.5281/zenodo.7868168) under the SynthRAD2023 collection. The images for each subject are available in nifti format.
Potential applications: This dataset will enable the evaluation and development of image synthesis algorithms for radiotherapy purposes on a realistic multi-center dataset with varying acquisition protocols. Synthetic CT generation has numerous applications in radiation therapy, including diagnosis, treatment planning, treatment monitoring, and surgical planning.
Keywords: artificial intelligence; computed tomography; deep learning; magnetic resonance imaging; synthetic CT.
© 2023 The Authors. Medical Physics published by Wiley Periodicals LLC on behalf of American Association of Physicists in Medicine.