Incidence, severity and detection of blood pressure and heart rate perturbations in postoperative ward patients after noncardiac surgery

J Clin Anesth. 2023 Oct:89:111159. doi: 10.1016/j.jclinane.2023.111159. Epub 2023 Jun 8.

Abstract

Study objective: We sought to determine changes in continuous mean and systolic blood pressure and heart rate in a cohort of non-cardiac surgical patients recovering on the postoperative ward. Furthermore, we estimated the proportion of vital signs changes that would remain undetected with intermittent vital signs checks.

Design: Retrospective cohort.

Setting: Post-operative general ward.

Patients: 14,623 adults recovering from non-cardiac surgical procedures.

Interventions & measurements: Using a wireless, noninvasive monitor, we recorded postoperative blood pressure and heart rate at 15-s intervals and encouraged nursing intervention as clinically indicated.

Main results: 7% of our cohort of 14,623 patients spent >15 sustained minutes with a MAP <65 mmHg, and 23% had MAP <75 mmHg for 15 sustained minutes. Hypertension was more common, with 67% of patients spending at least 60 sustained minutes with MAP >110 mmHg. Systolic pressures <90 mmHg were present for 15 sustained minutes in about a fifth of all patients, and 40% of patients had pressures >160 mmHg sustained for 30 min. 40% of patients were tachycardic with heart rates >100 beats/min for at least continuous 15 min and 15% of patients were bradycardic at a threshold of <50 beats/min for 5 sustained minutes. Conventional vital sign assessments at 4-h intervals would have missed 54% of mean pressure episodes <65 mmHg sustained >15 min, 20% of episodes of mean pressures >130 mmHg sustained >30 min, 36% of episodes of heart rate > 120 beats/min sustained <10 min, and 68% of episodes of heart rate sustained <40 beats per minute for >3 min.

Conclusions: Substantial hemodynamic disturbances persisted despite implementing continuous portable ward monitoring coupled with nursing alarms and interventions. A significant proportion of these changes would have gone undetected using traditional intermittent monitoring. Better understanding of effective responses to alarms and appropriate interventions on hospital wards remains necessary.

Keywords: Blood pressure; Continuous; Heart rate; Monitoring; Vital signs.

Publication types

  • Research Support, N.I.H., Extramural
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Adult
  • Blood Pressure
  • Heart Rate
  • Hospitals*
  • Humans
  • Incidence
  • Retrospective Studies
  • Vital Signs*