Background: Rapid shallow breathing index (RSBI) has been widely used as a predictor of extubation outcome in mechanically ventilated patients. We hypothesize that the rate of change of RSBI between the beginning and end of a 120-minute spontaneous breathing trial (SBT) could be a better predictor of extubation outcome than a single RSBI measured at the end of SBT in mechanically ventilated patients. Methodology. In this prospective observational study, we enrolled 193 patients who met the inclusion criteria, of whom 33 patients were unable to tolerate a 120-minute SBT and were excluded from the study. The study population consisted of 160 patients, categorized into three subgroups: patients with normal lung (no reported history of respiratory diseases), patients with airway disease, and patients with parenchymal disease who completed 120 minutes of SBT on low levels of pressure support ventilation. RSBI was obtained from the ventilator display at the 5th and the 120th minutes of SBT. The rate of change of RSBI (RSBI 5-120) was calculated as (RSBI 2-RSBI 1)/RSBI 1 × 100. Receiver-operating characteristic (ROC) curves were plotted for RSBI 5-120 and RSBI 120 in all patients and among the three subgroups (normal group, airway group, and parenchymal group) to compare the superiority of their best thresholds in predicting extubation failure.
Results: The RSBI 5-120 threshold for extubation failure in the entire patient group was 23% with an overall accuracy of 88% (AUC = 0.933, sensitivity = 91%, and specificity = 86%) and the threshold of RSBI 120 for extubation failure in the entire patient group was 70 breaths/min/L with an overall accuracy of 82% (AUC = 0.899, sensitivity = 85%, and specificity = 81%). In patients in the normal lung group, the threshold of RSBI 5-120 was 22%, with an overall accuracy of 89% (AUC = 0.892, sensitivity = 87.5%, and specificity = 90%), and the RSBI 120 threshold was 70 breaths/min/L, with an overall accuracy of 89% (AUC = 0.956, sensitivity = 88%, and specificity = 90%). The RSBI 5-120 threshold in patients with airway disease was 25% with an accuracy of 86% (AUC = 0.892, sensitivity = 85%, and specificity = 86%) and the threshold of RSBI 120 was 73 breaths/min/L with an accuracy of 83% (AUC = 0.874, sensitivity = 85%, and specificity = 82%). In patients in the parenchymal disease group, the threshold of RSBI 5-120 was 24%, with an accuracy of 90% (AUC = 0.966, sensitivity = 92%, and specificity = 89%) and RSBI 120 threshold was 71 breaths/min/L, which was 88% accurate (AUC = 0.893, sensitivity = 85%, and specificity = 89%).
Conclusion: The rate of change of RSBI between the 5th and 120th minutes was moderately more accurate than the single value of RSBI measured at the 120th minute in predicting extubation outcome.
Copyright © 2023 Manjush Karthika et al.