Technical note: Optimization functions for re-irradiation treatment planning

Med Phys. 2024 Jan;51(1):476-484. doi: 10.1002/mp.16815. Epub 2023 Nov 3.

Abstract

Background: Although re-irradiation is increasingly used in clinical practice, almost no dedicated planning software exists.

Purpose: Standard dose-based optimization functions were adjusted for re-irradiation planning using accumulated equivalent dose in 2-Gy fractions (EQD2) with rigid or deformable dose mapping, tissue-specific α/β, treatment-specific recovery coefficients, and voxelwise adjusted EQD2 penalization levels based on the estimated previously delivered EQD2 (EQD2deliv ).

Methods: To demonstrate proof-of-concept, 35 Gy in 5 fractions was planned to a fictitious spherical relapse planning target volume (PTV) in three separate locations following previous prostate treatment on a virtual human phantom. The PTV locations represented one repeated irradiation scenario and two re-irradiation scenarios. For each scenario, three re-planning strategies with identical PTV dose-functions but various organ at risk (OAR) EQD2-functions was used: 1) reRTregular : Regular functions with fixed EQD2 penalization levels larger than EQD2deliv for all OAR voxels. 2) reRTreduce : As reRTregular , but with lower fixed EQD2 penalization levels aiming to reduce OAR EQD2. 3) reRTvoxelwise : As reRTregular and reRTreduce , but with voxelwise adjusted EQD2 penalization levels based on EQD2deliv . PTV near-minimum and near-maximum dose (D98% /D2% ), homogeneity index (HI), conformity index (CI) and accumulated OAR EQD2 (α/β = 3 Gy) were evaluated.

Results: For the repeated irradiation scenario, all strategies resulted in similar dose distributions. For the re-irradiation scenarios, reRTreduce and reRTvoxelwise reduced accumulated average and near-maximum EQD2 by ˜1-10 Gy for all relevant OARs compared to reRTregular . The reduced OAR doses for reRTreduce came at the cost of distorted dose distributions with D98% = 92.3%, HI = 12.0%, CI = 73.7% and normal tissue hot spots ≥150% for the most complex scenario, while reRTregular (D98% = 98.1%, HI = 3.2%, CI = 94.2%) and reRTvoxelwise (D98% = 96.9%, HI = 6.1%, CI = 93.7%) fulfilled PTV coverage without hot spots.

Conclusions: The proposed re-irradiation-specific EQD2-based optimization functions introduce novel planning possibilities with flexible options to guide the trade-off between target coverage and OAR sparing with voxelwise adapted penalization levels based on EQD2deliv .

Keywords: equivalent dose; optimization functions; re-irradiation.

MeSH terms

  • Humans
  • Male
  • Organs at Risk / radiation effects
  • Radiotherapy Dosage
  • Radiotherapy Planning, Computer-Assisted / methods
  • Radiotherapy, Intensity-Modulated* / methods
  • Re-Irradiation*