Introduction: The purpose of this study was to evaluate the ability of the Reciproc, Reciproc Blue, and WaveOne Gold systems to remove filling material during endodontic retreatment of extracted human mandibular premolars.
Methods: Thirty-nine teeth were instrumented with the Protaper Universal System to the F3 file and filled with the Tagger hybrid technique using an F3 gutta-percha cone and AH Plus cement. At the end of this period, the teeth were scanned with micro-computed tomography before and after removal of the filling material from the root canals. The teeth were divided into 3 groups (n = 13) based on the apical volume, depending on the systems used to remove the filling material. Group GR: Reciproc 40/.06; Group GRB: Reciproc Blue 40/.06; and Group GWG: WaveOne Gold 35/.06. The results were statistically analyzed using the tests of Kruskal-Wallis, Duncan, and analysis of variance at a significance level of 5%.
Results: The results showed that there were no significant differences between the amounts of filling material removed, either for the apical and middle regions alone or in the overall evaluation for the 3 groups (P = .97). The time evaluation statistically showed that the GR and GWG groups required less time to clean the root canals than the GRB group.
Conclusions: Reciproc R40 files and WaveOne Gold Medium files required less time for endodontic treatment than Reciproc Blue R40 files. There was no difference in the ability to remove obturation material between the 3 instruments. No instrument was able to completely remove the filling material from the root canals.
Keywords: Endodontics; micro-CT; reciprocating instruments; retreatment.
Copyright © 2023 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.