Background: The potentially higher risk of hemorrhagic complications is of concern in stent-assisted coiling (SAC) of ruptured wide-necked intracranial aneurysms (IAs). The Woven EndoBridge (WEB) is considered an appealing alternative since antiplatelet therapy is not required. Herein, we aimed to compare the safety and effectiveness of WEB vs. SAC for the treatment of ruptured wide-necked IAs.
Methods: This was an international cross-sectional study of consecutive patients treated for ruptured wide-neck IAs with WEB or SAC at four high-volume neurovascular centers between 2019 and 2022. Primary and secondary efficacy outcomes were radiographic aneurysm occlusion at follow-up and functional status at last follow-up. Safety outcomes included periprocedural hemorrhagic/ischemia-related complications.
Results: One hundred five patients treated with WEB and 112 patients treated with SAC were included. The median procedure duration of endovascular treatment was shorter for WEB than for SAC (69 vs. 76 min; p = 0.04). There were no significant differences in complete aneurysm occlusion rates (SAC: 64.5% vs. WEB: 60.9%; adjusted OR [aOR] = 0.70; 95%CI 0.34-1.43; p = 0.328). SAC had a significantly higher risk of complications (23.2% vs. 9.5%, p = 0.009), ischemic events (17% vs. 6.7%, p = 0.024), and EVD hemorrhage (16% vs. 0%, p = 0.008). The probability of procedure-related complications across procedure time was significantly lower with WEB compared with SAC (aOR = 0.40; 95%CI 0.20-1.13; p = 0.03).
Conclusion: WEB and SAC demonstrated similar obliteration rates at follow-up when used for embolization of ruptured wide-necked IAs. However, SAC showed higher rates of procedure-related complications primarily driven by ischemic events and higher rates of EVD hemorrhage. The overall treatment duration was shorter for WEB than for SAC.
Keywords: Intracranial aneurysm; Woven EndoBridge device; endovascular treatment; stent-assisted coiling.