Background: The origins and timing of inpatient room sink contamination with carbapenem-resistant organisms (CROs) are poorly understood.
Methods: We performed a prospective observational study to describe the timing, rate, and frequency of CRO contamination of in-room handwashing sinks in 2 intensive care units (ICU) in a newly constructed hospital bed tower. Study units, A and B, were opened to patient care in succession. The patients in unit A were moved to a new unit in the same bed tower, unit B. Each unit was similarly designed with 26 rooms and in-room sinks. Microbiological samples were taken every 4 weeks from 3 locations from each study sink: the top of the bowl, the drain cover, and the p-trap. The primary outcome was sink conversion events (SCEs), defined as CRO contamination of a sink in which CRO had not previously been detected.
Results: Sink samples were obtained 22 times from September 2020 to June 2022, giving 1,638 total environmental cultures. In total, 2,814 patients were admitted to study units while sink sampling occurred. We observed 35 SCEs (73%) overall; 9 sinks (41%) in unit A became contaminated with CRO by month 10, and all 26 sinks became contaminated in unit B by month 7. Overall, 299 CRO isolates were recovered; the most common species were Enterobacter cloacae and Pseudomonas aeruginosa.
Conclusion: CRO contamination of sinks in 2 newly constructed ICUs was rapid and cumulative. Our findings support in-room sinks as reservoirs of CRO and emphasize the need for prevention strategies to mitigate contamination of hands and surfaces from CRO-colonized sinks.