Abstract

Multiplexing is a relevant strategy for biosensors to improve accuracy and decision-making due to the increased amount of simultaneously obtained information. Liposomes offer unique benefits for label-based multiplexing since a variety of different marker molecules can be encapsulated, leading to intrinsic signal amplification and enabling a variety of detection formats. We successfully developed an electrochemical (EC) liposome-based platform technology for the simultaneous detection of at least three analytes by studying parameters to ensure specific and sensitive bioassay performance. Influenza A and B and SARS-CoV-2 sequences served as model system in a standard sandwich hybridization assay. Studies included encapsulants, probe distribution on liposomes and capture beads, assay setup and interferences between liposomes to also ensure a generalization of the platform. Ruthenium hexamine(III), potassium hexacyanoferrate(II) and m-carboxy luminol, when encapsulated separately into a liposome, provided desirable long-term stability of at least 12 months and no cross-signals between liposomes. Through the optimization process, low limits of detections of 1.6 nmol L-1, 125 pmol L-1 and 130 pmol L-1, respectively, were achieved in a multiplexed assay setup, which were similar to singleplex assays. Non-specific interactions were limited to 25.1%, 7.6% and 7.5%, respectively, through sequential liposome incubations and singleplex capture bead designs. Here, ruthenium hexamine liposomes had only mediocre performance so that low overall signal strength translated into higher LODs and worse specificity. A different marker such as ferroin may be an option in the future. The identification of further electrochemical markers will provide new opportunities for liposomes to function as multiplex, orthogonal or internal standard labels in electrochemical bioassays.

Keywords: DNA; Electrochemical biosensor; Laser-induced graphene; Liposomes; Multiplex; SARS-CoV-2.

MeSH terms

  • Biosensing Techniques / methods
  • COVID-19 / diagnosis
  • COVID-19 / virology
  • Electrochemical Techniques* / methods
  • Humans
  • Influenza A virus / isolation & purification
  • Influenza B virus* / isolation & purification
  • Influenza, Human / diagnosis
  • Influenza, Human / virology
  • Limit of Detection*
  • Liposomes* / chemistry
  • SARS-CoV-2* / genetics
  • SARS-CoV-2* / isolation & purification

Substances