Objective: Evidence supports replacement over repair for ischemic mitral regurgitation due to improved durability; however, the latter often involves an undersized ring annuloplasty that does not include edge-to-edge approximation. The objective of this study was to evaluate the outcomes of replacement, edge-to-edge leaflet approximation with mild-undersized annuloplasty and undersized ring annuloplasty for ischemic mitral regurgitation.
Methods: This is a single-center retrospective study of patients undergoing mitral surgery for moderate-severe or greater ischemic mitral regurgitation, between 2004 and 2020, with mild-undersized annuloplasty, mitral valve replacement, or undersized restrictive annuloplasty (undersized ring annuloplasty). The primary outcome was all-cause mortality. Secondary outcomes included first recurrence of mitral regurgitation, heart failure hospitalization, and composite of valve-related events (bleeding, thromboembolism, endocarditis, and mitral valve reoperation).
Results: There were 121, 93, and 78 patients in the mitral valve replacement, mild-undersized annuloplasty, and undersized restrictive annuloplasty groups, respectively, with a median follow-up of 3.1, 5.9, and 3.8 years, respectively. Both mitral valve replacement (hazard ratio, 1.87; 95% CI, 1.029-3.415) and undersized restrictive annuloplasty (hazard ratio, 2.73; 95% CI, 1.480-5.061) were associated with worse survival compared with mild-undersized annuloplasty. At 2 years, the rate of mild-moderate mitral regurgitation was greater in the mild-undersized annuloplasty group compared with the mitral valve replacement group (P = .001) but less than in the undersized restrictive annuloplasty group (P = .001). The rate of recurrent moderate or greater mitral regurgitation at 2 years was similar between mild-undersized annuloplasty and mitral valve replacement groups but significantly higher after undersized restrictive annuloplasty (P < .0001). Mitral valve replacement and undersized restrictive annuloplasty were associated with a significant increase in the incidence of first heart failure hospitalization compared with mild-undersized annuloplasty (P < .001 and P = .001, respectively). Mitral valve replacement was associated with an increased incidence of valve-related events compared with mild-undersized annuloplasty (P = .002).
Conclusions: Surgical edge-to-edge approximation in addition to a mild-undersizing annuloplasty offers similar durability compared with replacement, with a lower rate of hospitalization for heart failure, and may confer a survival advantage.
Keywords: edge-to-edge repair; heart failure; ischemic mitral regurgitation; mitral valve repair; mitral valve replacement.
© 2023 The Author(s).