Intra-patient and inter-observer image quality analysis in liver MRI study with gadoxetic acid using two different multi-arterial phase techniques

Br J Radiol. 2024 Mar 28;97(1156):868-873. doi: 10.1093/bjr/tqae045.

Abstract

Purpose: To evaluate intra-patient and interobserver agreement in patients who underwent liver MRI with gadoxetic acid using two different multi-arterial phase (AP) techniques.

Methods: A total of 154 prospectively enrolled patients underwent clinical gadoxetic acid-enhanced liver MRI twice within 12 months, using two different multi-arterial algorithms: CAIPIRINHA-VIBE and TWIST-VIBE. For every patient, breath-holding time, body mass index, sex, age were recorded. The phase without contrast media and the APs were independently evaluated by two radiologists who quantified Gibbs artefacts, noise, respiratory motion artefacts, and general image quality. Presence or absence of Gibbs artefacts and noise was compared by the McNemar's test. Respiratory motion artefacts and image quality scores were compared using Wilcoxon signed rank test. Interobserver agreement was assessed by Cohen kappa statistics.

Results: Compared with TWIST-VIBE, CAIPIRINHA-VIBE images had better scores for every parameter except higher noise score. Triple APs were always acquired with TWIST-VIBE but failed in 37% using CAIPIRINHA-VIBE: 11% have only one AP, 26% have two. Breath-holding time was the only parameter that influenced the success of multi-arterial techniques. TWIST-VIBE images had worst score for Gibbs and respiratory motion artefacts but lower noise score.

Conclusion: CAIPIRINHA-VIBE images were always diagnostic, but with a failure of triple-AP in 37%. TWIST-VIBE was successful in obtaining three APs in all patients. Breath-holding time is the only parameter which can influence the preliminary choice between CAIPIRINHA-VIBE and TWIST-VIBE algorithm.

Advances in knowledge: If the patient is expected to perform good breath-holds, TWIST-VIBE is preferable; otherwise, CAIPIRINHA-VIBE is more appropriate.

Keywords: CAIPIRINHA-VIBE; TWIST-VIBE; gadoxetic acid liver MRI; multi-arterial phase techniques.

MeSH terms

  • Artifacts
  • Breath Holding
  • Contrast Media
  • Gadolinium DTPA*
  • Humans
  • Image Enhancement* / methods
  • Image Interpretation, Computer-Assisted* / methods
  • Liver / diagnostic imaging
  • Magnetic Resonance Imaging / methods
  • Reproducibility of Results

Substances

  • gadolinium ethoxybenzyl DTPA
  • Contrast Media
  • Gadolinium DTPA