Objectives: Right ventricular failure following implantation of a durable left ventricular assist device (LVAD) is a major driver of mortality. Reported survival following biventricular (BiVAD) or total artificial heart (TAH) implantation remains substantially inferior to LVAD alone. We report our outcomes with LVAD and BiVAD HeartMate 3 (HM3).
Methods: Consecutive patients undergoing implantation of an HM3 LVAD between November 2014 and December 2021, at The Alfred, Australia were included in the study. Comparison was made between the BiVAD and LVAD alone groups.
Results: A total of 86 patients, 65 patients with LVAD alone and 21 in a BiVAD configuration underwent implantation. The median age of the LVAD and BiVAD groups was 56 years (Interquartile range 46-62) and 49 years (Interquartile range 37-55), respectively. By 4 years after implantation, 54% of LVAD patients and 43% of BiVAD patients had undergone cardiac transplantation. The incidence of stroke in the entire experience was 3.5% and pump thrombosis 5% (all in the RVAD). There were 14 deaths in the LVAD group and 1 in the BiVAD group. The actuarial survival for LVAD patients at 1 year was 85% and BiVAD patients at 1 year was 95%.
Conclusions: The application of HM 3 BiVAD support in selected patients appears to offer a satisfactory solution to patients requiring biventricular support.
Keywords: circulatory support devices; right heart failure; ventricular assist device.