Evaluation of SARS-CoV-2 quantification from oropharyngeal swabs, nasopharyngeal swabs, and naso-oropharyngeal swabs: A cross-sectional study

Heliyon. 2024 Mar 23;10(7):e28647. doi: 10.1016/j.heliyon.2024.e28647. eCollection 2024 Apr 15.

Abstract

The current naso-oropharyngeal swab for SARS-CoV-2 detection faces several problems, such as waste issues and its use for quantitative studies. This study aimed to evaluate the total RNA and viral loads from different upper respiratory tract swabs types and whether SARS-CoV-2 quantification can use the current internal control for normalization. This cross-sectional study collected positive specimens with single oropharyngeal or nasopharyngeal swabs and naso-oropharyngeal swabs. The samples were extracted, tested with qualitative RT‒PCR, and then tested with quantitative RT‒PCR. The RNA eluate was measured for the total RNA concentration. The total RNA concentration, viral load, and RNaseP Ct values were collected and analysed statistically. The positive results came from 41 oropharyngeal swabs, 34 nasopharyngeal swabs, and 36 naso-oropharyngeal swabs. The total RNA increased significantly from oropharyngeal swabs to nasopharyngeal swabs to naso-oropharyngeal swabs. Significant differences in RNaseP Ct values between groups and their correlations with total RNA were found. In addition, the increase in the total RNA and the RNaseP Ct values were unrelated to the viral load. The physical features in the naso-oropharyngeal area and the swabbing procedures could affect the total RNA but not the viral load. However, since the virus particles could present inside and outside human cells, the increase in collected human cells may not always be followed by the viral load increase. Normalization using the RNaseP Ct value became unnecessary due to the factors mentioned above. Therefore, a careful approach is needed in viral load studies of swab specimens.

Keywords: Quantitative PCR; SARS-Cov-2; Total RNA; Viral load.