[Application of metal cushion block combined with Jumbo cup in reconstruction of acetabular bone defect in revision of artificial hip joint]

Zhongguo Gu Shang. 2024 May 25;37(5):464-9. doi: 10.12200/j.issn.1003-0034.20220877.
[Article in Chinese]

Abstract

Objective: To investigate the application effect and imaging changes of metal cushion block combined with Jumbo cup in the reconstruction of acetabular bone defect after revision of artificial hip joint.

Methods: Retrospective analysis was made on the clinical data of 83 patients who underwent revision acetabular bone defect reconstruction of the artificial hip joint in our hospital from September 2019 to October 2021. They were divided into group A and group B according to different surgical methods. There were 42 patients in group A, including 26 males and 16 females, aged from 44 to 72 years old with an average of (60.57±4.62) years, who underwent revision with metal cushion block and Jumbo cup. There were 41 patients in group B, including 22 males and 19 females, aged from 42 to 71 years old with an average of (58.74±4.25) years, who underwent revision with metal cushion block and bone cement mortar cup. The operation related indexes, Harris hip function score and visual analogue scale (VAS) of pain before operation, 1 month and 12 month after operation were compared between two groups. The results of X-ray imaging examination (hip rotation center height, acetabular abduction angle, femoral eccentricity and imaging standard qualification rate) before and 12 month after operation were evaluated, and the incidence of complications was compared between two groups.

Results: There was no significant difference in operation time, intraoperative bleeding volume and postoperative drainage volume between two groups (P>0.05). Both groups were followed up for 12 to 36 months with an average of (25.36±3.59) months. The scores of pain, function, deformity and Harris' total score in the two groups at 1 month after operation were higher than those before operation (P<0.05), and the scores of pain, function, deformity, joint activity and Harris' total score in two groups at 1 year after operation were higher than those before operation and 1 month after operation (P<0.05), and the above scores in group A were higher than those in group B at 1 year after operation (P<0.05). The VAS of two groups decreased successively at 1 month and 1 year after operation (P<0.05), but there was no significant difference in both groups at each time point (P>0.05). The femoral eccentricity increased in both groups at 1 year after operation (P<0.05), and group A was higher than group B (P<0.05). The height of rotation center and acetabular abduction angle decreased in both groups at 1 year after operation (P<0.05), and the height of rotation center in group A was lower than that in group B (P<0.05), but there was no significant difference in acetabular abduction angle between two groups (P>0.05). The imaging qualification rate of group A was higher than that of group B (P<0.05). There was no significant difference in the incidence of adverse reactions between two groups (P>0.05).

Conclusion: Metal cushion block combined with Jumbo cup in the treatment of acetabular bone defects can provide the hip joint function, and restore the hip joint rotation center, femoral eccentricity and acetabular abduction angle, with obvious clinical effect.

Keywords: Acetabular bone defect; Jumbo cup; Metal cushion block; Revision of artificial hip joint.

Publication types

  • English Abstract

MeSH terms

  • Acetabulum* / surgery
  • Adult
  • Aged
  • Arthroplasty, Replacement, Hip* / methods
  • Female
  • Hip Prosthesis
  • Humans
  • Male
  • Metals
  • Middle Aged
  • Plastic Surgery Procedures / methods
  • Reoperation
  • Retrospective Studies

Substances

  • Metals