Background: Complete removal of cardiac implantable electronic devices (CIEDs) is recommended in patients with CIED infections, including both systemic and localized pocket infection. The aim of the study was to provide an up-to-date and comprehensive assessment of evidence relating to the effect of complete CIED extraction in patients with a CIED infection.
Methods: We performed a systematic review and meta-analysis of studies reporting short- and mid-term outcomes in patients who had a device infection or infective endocarditis (IE) and underwent complete removal of the cardiac device (generator and leads) compared to those who received conservative therapy (no removal, partial removal, local antibiotic infiltration or isolated antibiotic therapy). The primary outcome was reinfection/relapse. Secondary outcomes were short-term (30-day/in-hospital) and mid-term (mean follow-up: 43.0 months) mortality. Random effects model was performed.
Results: Thirty-two studies met the criteria for inclusion in the final analysis. Patients with complete CIED extraction (n = 905) exhibited a lower rate of relapse/re-infection compared to patients (n = 195) with a conservative treatment approach (n = 195, OR 0.02, 95%CI 0.01-0.06, p < 0.0001, mean-follow-up: 16.1 months). Additionally, these patients displayed a lower short- (OR 0.40, 95%CI 0.23-0.69, p = 0.01) and mid-term (OR 0.52, 95%CI 0.34-0.78, p = 0.002) mortality.
Conclusions: The analysis indicates that patients with a CIED infection who undergo complete CIED extraction exhibit a lower rate of relapse/re-infection. Additionally, a lower short- and mid-term mortality is observed, although it is acknowledged that this outcome may be influenced by treatment allocation bias.
Keywords: Device infection; Device removal; Infective endocarditis.
Copyright © 2024 The Authors. Published by Elsevier B.V. All rights reserved.