Tracheobronchial foreign body (TFB) aspiration is an uncommon but potentially life-threatening event. This case report discusses the successful extraction of a metallic screw aspirated by a 48-year-old woman with intellectual disability, using flexible bronchoscopy through the i-gel® laryngeal mask under general anesthesia. The i-gel® device proved effective in maintaining airway access and facilitating bronchoscopy, emphasizing its utility in challenging cases. The report underscores the significance of careful assessment, skillful intervention, and multidisciplinary teamwork in managing TFB aspirations, especially in uncooperative patients with comorbidities.
Keywords: Flexible bronchoscopy; I-gel® laryngeal mask; Tracheobronchial foreign body aspiration.
© Indian Association of Cardiovascular-Thoracic Surgeons 2024. Springer Nature or its licensor (e.g. a society or other partner) holds exclusive rights to this article under a publishing agreement with the author(s) or other rightsholder(s); author self-archiving of the accepted manuscript version of this article is solely governed by the terms of such publishing agreement and applicable law.