Intraindividual Comparison of Dose Reduction and Coronary Calcium Scoring Accuracy Using Kilovolt-independent and Tin Filtration CT Protocols

Radiol Cardiothorac Imaging. 2024 Jun;6(3):e230246. doi: 10.1148/ryct.230246.

Abstract

Purpose To investigate the ability of kilovolt-independent (hereafter, kV-independent) and tin filter spectral shaping to accurately quantify the coronary artery calcium score (CACS) and radiation dose reductions compared with the standard 120-kV CT protocol. Materials and Methods This prospective, blinded reader study included 201 participants (mean age, 60 years ± 9.8 [SD]; 119 female, 82 male) who underwent standard 120-kV CT and additional kV-independent and tin filter research CT scans from October 2020 to July 2021. Scans were reconstructed using a Qr36f kernel for standard scans and an Sa36f kernel for research scans simulating artificial 120-kV images. CACS, risk categorization, and radiation doses were compared by analyzing data with analysis of variance, Kruskal-Wallis test, Mann-Whitney test, Bland-Altman analysis, Pearson correlations, and κ analysis for agreement. Results There was no evidence of differences in CACS across standard 120-kV, kV-independent, and tin filter scans, with median CACS values of 1 (IQR, 0-48), 0.6 (IQR, 0-58), and 0 (IQR, 0-51), respectively (P = .85). Compared with standard 120-kV scans, kV-independent and tin filter scans showed excellent correlation in CACS values (r = 0.993 and r = 0.999, respectively), with high agreement in CACS risk categorization (κ = 0.95 and κ = 0.93, respectively). Standard 120-kV scans had a mean radiation dose of 2.09 mSv ± 0.84, while kV-independent and tin filter scans reduced it to 1.21 mSv ± 0.85 and 0.26 mSv ± 0.11, cutting doses by 42% and 87%, respectively (P < .001). Conclusion The kV-independent and tin filter research CT acquisition techniques showed excellent agreement and high accuracy in CACS estimation compared with standard 120-kV scans, with large reductions in radiation dose. Keywords: CT, Cardiac, Coronary Arteries, Radiation Safety, Coronary Artery Calcium Score, Radiation Dose Reduction, Low-Dose CT Scan, Tin Filter, kV-Independent Supplemental material is available for this article. © RSNA, 2024.

Keywords: CT; Cardiac; Coronary Arteries; Coronary Artery Calcium Score; Low-Dose CT Scan; Radiation Dose Reduction; Radiation Safety; Tin Filter; kV-Independent.

Publication types

  • Comparative Study

MeSH terms

  • Aged
  • Coronary Angiography / methods
  • Coronary Artery Disease* / diagnostic imaging
  • Coronary Vessels* / diagnostic imaging
  • Female
  • Humans
  • Male
  • Middle Aged
  • Prospective Studies
  • Radiation Dosage*
  • Reproducibility of Results
  • Tin / chemistry
  • Tomography, X-Ray Computed / methods
  • Vascular Calcification / diagnostic imaging

Substances

  • Tin