Background: Knowledge about impact of age and comorbidities on outcome in patients with leadless pacemakers (LPM) is limited.
Objectives: To analyse outcome in LPM patients according to age and comorbidities.
Methods: This Swiss, multi-centre, retrospective analysis includes all patients with LPM implanted between 2015 and 2022. Charlson-Comorbidity-Index (CCI) was determined and patients were divided into a low- (CCI ≤ 5) and high-comorbidity (CCI > 5) group. Peri-procedural complications, in-hospital death, and all-cause mortalities were assessed. Finally, all-cause mortality according to three groups (CCI ≤ 3, 4-5, >5) was compared to age and sex-adjusted mortality in the general Swiss population.
Results: 863 patients (median age 81 years, 65% male, 42% with CCI > 5) were included. Peri-procedural/long-term complication rates did not differ between the low- vs. high-comorbidity groups (2.6% vs. 1.7%, p = 0.48 and 1.2% vs. 2.8%, p = 0.12, respectively). In-hospital (3.6% vs. 0.6%, p = 0.002) and all-cause mortality (HR 2.9, 95%CI 2.2-3.8, p < 0.001) were significantly higher in the high-comorbidity group resulting in a three-year mortality of 58% (95%CI 51-65%) vs. 22% (95%CI 17-27%) in the low-comorbidity group. In patients with a CCI ≤ 3, all-cause mortality was comparable to the age- and sex-adjusted mortality of the general Swiss population.
Conclusions: In elderly patients with high comorbidity, LPM implantation was not associated with increased peri-procedural/long-term complications. All-cause mortality in LPM patients with a CCI ≤ 3 was comparable to age- and sex-adjusted mortality in the general Swiss population. Despite a relatively high three-year mortality due to competing risk factors, LPM implantation is safe, even in elderly patients with high comorbidity.
Condensed abstract: In this Swiss, multi-centre, retrospective cohort analysis, 863 patients implanted with a leadless pacemaker were included and divided into a high-comorbidity (with a CCI > 5) and low-comorbidity (with a CCI ≤ 5) group. There was no between group difference in terms of implantation outcomes and peri-operative or long-term complications. Furthermore, all-cause mortality during follow-up in patients with a CCI ≤ 3 was comparable to age- and sex-adjusted mortality in the general Swiss population. These data indicate that LPM implantation is a safe procedure, even in elderly patients with high comorbidity.
Keywords: Charlson comorbidity index; Complication; Leadless pacemaker; Micra; Transcatheter pacemaker.
Copyright © 2024 The Authors. Published by Elsevier B.V. All rights reserved.