3-Year Outcomes of Balloon-Expandable Valves: 20-mm vs Larger Valves (≥23 mm)

JACC Cardiovasc Interv. 2024 Sep 9;17(17):2041-2051. doi: 10.1016/j.jcin.2024.06.001. Epub 2024 Aug 21.

Abstract

Background: A prior Society of Thoracic Surgeons/American College of Cardiology TVT (Transcatheter Valve Therapy) Registry-based analysis reported similar 1-year clinical outcomes with small (20-mm) vs large (≥23-mm) balloon-expandable valves (BEV).

Objectives: The aim of this study was to describe mid-term 3-year clinical outcomes for small vs large BEV and the relationship between discharge echocardiographic mean gradient (MG) and different definitions of prothesis-patient mismatch (PPM) with clinical outcomes.

Methods: Using the TVT Registry with Centers for Medicare and Medicaid Services linkage, a propensity-matched analysis of patients receiving 20- vs ≥23-mm BEVs was performed. Spline curves and Kaplan-Meier plots with adjusted HRs determined the relationship between MG and 3-year mortality.

Results: In total, 316,091 patients were analyzed; after propensity matching, 8,100 pairs of each group were compared. The 20-mm BEV was associated with higher MGs compared with ≥23-mm BEVs (16.2 ± 7.2 mm Hg vs 11.8 ± 5.7 mm Hg; P < 0.0001). At 3 years, there was no difference in mortality between 20- and ≥23-mm BEVs (31.5% vs 32.5%, respectively; HR: 0.97; 95% CI: 0.90-1.05). Compared with an MG of 10 to 30 mm Hg, an MG <10 mm Hg (HR: 1.25; 95% CI:1.22-1.27) was associated with increased 3-year mortality. Measured severe PPM and predicted no PPM were associated with increased 3-year mortality (33.5% vs 32.9% vs 32.1%; P < 0.0001) and (33.5% vs 31.1% vs 30%; P < 0.0001), respectively. Low MG and severe measured PPM were associated with lower left ventricular ejection fraction (LVEF).

Conclusions: Patients with small-prosthesis BEVs (20 mm) had identical 3-year survival as those with larger (≥23-mm) BEV valves. Severe measured PPM and low MG (<10 mm Hg), but not predicted severe PPM, were associated with lower LVEF and increased mortality, suggesting that LVEF is the culprit for worse outcomes.

Keywords: SAPIEN valve; balloon-expandable valves; clinical outcomes; hemodynamic status; transcatheter aortic valve replacement; valvular heart disease.

Publication types

  • Comparative Study

MeSH terms

  • Aged
  • Aged, 80 and over
  • Aortic Valve Stenosis / diagnostic imaging
  • Aortic Valve Stenosis / mortality
  • Aortic Valve Stenosis / physiopathology
  • Aortic Valve Stenosis / surgery
  • Aortic Valve* / diagnostic imaging
  • Aortic Valve* / physiopathology
  • Aortic Valve* / surgery
  • Balloon Valvuloplasty* / adverse effects
  • Balloon Valvuloplasty* / mortality
  • Female
  • Heart Valve Prosthesis Implantation / adverse effects
  • Heart Valve Prosthesis Implantation / instrumentation
  • Heart Valve Prosthesis Implantation / mortality
  • Heart Valve Prosthesis*
  • Hemodynamics
  • Humans
  • Male
  • Prosthesis Design*
  • Recovery of Function
  • Registries*
  • Retrospective Studies
  • Risk Assessment
  • Risk Factors
  • Time Factors
  • Transcatheter Aortic Valve Replacement / adverse effects
  • Transcatheter Aortic Valve Replacement / instrumentation
  • Transcatheter Aortic Valve Replacement / mortality
  • Treatment Outcome
  • United States