Purpose: To evaluate a novel flow-independent sequence (Relaxation-Enhanced Angiography without Contrast and Triggering (REACT)) for imaging of the extracranial arteries in acute ischemic stroke (AIS) at 1.5 T.
Methods: This retrospective single-center study included 47 AIS patients who received REACT (scan time: 3:01 min) and contrast-enhanced MRA (CE-MRA) of the extracranial arteries at 1.5 T in clinical routine. Two radiologists assessed scans for proximal internal carotid artery (ICA) stenosis, stated their diagnostic confidence and rated the image quality of cervical arteries, impact of artifacts and image noise. Apparent signal- and contrast-to-noise ratios (aSNR/aCNR) were measured for the common carotid artery and ICA.
Results: REACT achieved a sensitivity of 95.0% and a specificity of 97.3% for ICA stenoses in high agreement with CE-MRA (κ = 0.83) with equal diagnostic confidence (p = 0.22). Image quality was rated higher for CE-MRA at the aortic arch (p = 0.002) and vertebral arteries (p < 0.001), whereas REACT provided superior results for the extracranial ICA (p = 0.008). Both sequences were only slightly affected by artifacts (p = 0.60), while image noise was more pronounced in CE-MRA (p < 0.001) in line with higher aSNR (p < 0.001) and aCNR (p < 0.001) values in REACT for all vessels.
Conclusion: Given its good diagnostic performance while yielding comparable image quality and scan time to CE-MRA, REACT may be suitable for the imaging of the extracranial arteries in acute ischemic stroke at 1.5 T.
Keywords: Carotid arteries; ICA stenosis; Magnetic resonance angiography; Non-contrast-enhanced magnetic resonance angiography; Stroke.