Line-scan phase-resolved synthetic wavelength LiDAR using an off-axis holographic approach

Opt Lett. 2024 Oct 15;49(20):5755-5758. doi: 10.1364/OL.532480.

Abstract

We demonstrate a novel, to our knowledge, approach for phase-resolved coherent 3D surface imaging that utilizes synthetic wavelength phase-based ranging and line-scan off-axis holography. Our proof-of-concept system employs an akinetic tunable laser to perform fast wavelength switching and a galvanometer mirror for slow-axis mechanical scanning. Quantitative depth measurements of an anodized aluminum plate and 3D-printed depth calibration targets and a printed circuit board are demonstrated. Analyses of both shot-noise limited system performance and speckle noise are also presented. The proof-of-concept system achieves micron-scale depth precision with a FOV of 12.8 mm × 34 mm and a 50 ms image acquisition time.