Improved quality control of allergen products: Assessing the molecular allergen composition by mass spectrometry

Allergy. 2024 Oct 24. doi: 10.1111/all.16339. Online ahead of print.

Abstract

Background: Natural allergen sources contain a variety of allergens, against which allergic subjects have developed individual sensitization profiles. Ideal allergen products for skin prick testing (SPT) and allergen immunotherapy (AIT) should contain the complete set of allergens of the respective allergen sources to cover all sensitization profiles. However, commercially available allergen products were shown to vary regarding their allergen composition.

Methods: The qualitative allergen composition of different SPT and AIT products produced from pollen of grasses, birch, mugwort and from house dust mites was assessed by a consistent high-resolution liquid chromatography-coupled tandem mass spectrometry method (LC-MS/MS).

Results: All major, mid-tier and most minor allergens were detected in each of the investigated three batches of SPT and AIT products, demonstrating the completeness of the allergen composition and a high degree of batch-to-batch consistency.

Conclusion: This is the first study using a single consistent high-resolution LC-MS/MS method to provide solid data on the qualitative allergen composition of SPT and AIT products manufactured from various common allergen sources. The applied method showed high reliability in qualitative batch-to-batch consistency testing and can be performed fast and with high throughput. High-resolution LC-MS/MS is applicable for process development and quality control to ensure market availability of allergen products corresponding to the composition of the respective natural allergen sources.

Keywords: allergen composition; allergen immunotherapy; allergen products; house dust mites; mass spectrometry.