Extended Duration Bridge to Orthotopic Heart Transplant Utilizing the Impella RP Flex

ASAIO J. 2024 Dec 1;70(12):e188-e190. doi: 10.1097/MAT.0000000000002221. Epub 2024 May 2.

Abstract

We present a case of a 56 year old man presenting with cardiogenic shock from isolated right ventricular failure due to arrhythmogenic right ventricular cardiomyopathy who was successfully bridged to heart transplantation after 29 days on an Impella RP Flex right ventricular assist device. This represents the longest reported duration of support with the device to date and highlights the utility of this platform in the management of severe right ventricular failure.

Publication types

  • Case Reports

MeSH terms

  • Arrhythmogenic Right Ventricular Dysplasia / surgery
  • Arrhythmogenic Right Ventricular Dysplasia / therapy
  • Heart Failure* / surgery
  • Heart Failure* / therapy
  • Heart Transplantation* / methods
  • Heart-Assist Devices*
  • Humans
  • Male
  • Middle Aged
  • Shock, Cardiogenic / etiology
  • Shock, Cardiogenic / surgery
  • Shock, Cardiogenic / therapy
  • Time Factors