Influences of aortic pressure gradient and ventricular septal thickness with systolic coronary flow in aortic valve stenosis

Am J Cardiol. 1996 Dec 1;78(11):1303-6. doi: 10.1016/s0002-9149(96)00618-2.

Abstract

This study evaluates flow patterns of the left anterior descending and circumflex coronary arteries by multiplane transesophageal echocardiography in 25 patients with aortic valve stenosis, and assesses the relation between coronary flow characteristics and anatomic and hemodynamic parameters.

MeSH terms

  • Aortic Valve / physiopathology*
  • Aortic Valve Stenosis / diagnostic imaging
  • Aortic Valve Stenosis / physiopathology*
  • Aortic Valve Stenosis / surgery
  • Blood Flow Velocity / physiology
  • Coronary Circulation / physiology*
  • Echocardiography, Doppler, Pulsed
  • Echocardiography, Transesophageal
  • Heart Septum / ultrastructure*
  • Heart Valve Prosthesis
  • Hemodynamics / physiology*
  • Humans
  • Observer Variation
  • Pressure
  • Regression Analysis
  • Systole / physiology
  • Vascular Resistance