Abstract
A specific, sensitive, single-step solid-phase extraction and reversed-phase high-performance liquid chromatographic method for the simultaneous determination of plasma 6-mercaptopurine and azathioprine concentrations is reported. Following solid-phase extraction, analytes are separated on a C18 column with mobile phase consisting of 0.8% acetonitrile in 1 mM triethylamine, pH 3.2, run on a gradient system. Quantitation limits were 5 ng/ml and 2 ng/ml for azathioprine and 6-mercaptopurine, respectively. Peak heights correlated linearly to known extracted standards for 6-mercaptopurine and azathioprine (r = 0.999) over a range of 2-200 ng/ml. No chromatographic interferences were detected.
Publication types
-
Research Support, U.S. Gov't, Non-P.H.S.
MeSH terms
-
Administration, Oral
-
Adult
-
Antimetabolites, Antineoplastic / analysis
-
Antimetabolites, Antineoplastic / chemistry
-
Antimetabolites, Antineoplastic / pharmacokinetics
-
Antirheumatic Agents / blood*
-
Antirheumatic Agents / chemistry
-
Antirheumatic Agents / pharmacokinetics
-
Azathioprine / blood*
-
Azathioprine / chemistry
-
Azathioprine / pharmacokinetics
-
Chromatography, High Pressure Liquid / methods*
-
Drug Stability
-
Female
-
Humans
-
Immunosuppressive Agents / blood*
-
Immunosuppressive Agents / chemistry
-
Immunosuppressive Agents / pharmacokinetics
-
Mercaptopurine / blood*
-
Mercaptopurine / chemistry
-
Mercaptopurine / pharmacokinetics
-
Reproducibility of Results
-
Temperature
Substances
-
Antimetabolites, Antineoplastic
-
Antirheumatic Agents
-
Immunosuppressive Agents
-
Mercaptopurine
-
Azathioprine