Reliability of standardized echography before vitreoretinal surgery for proliferative diabetic retinopathy

Ophthalmologica. 1998:212 Suppl 1:91-2. doi: 10.1159/000055438.

Abstract

Standardized A- and B-scan echography was performed in 45 patients (68 eyes) affected by proliferative diabetic retinopathy, before vitreoretinal surgery, to evaluate the percentage of agreement between the ultrasonographic data and the surgical findings. The agreement was quite good for tractional retinal detachment (93%) and for posterior vitreous detachment (91%). The main cause of failure was the presence of vitreoschisis, while preretinal and vitreal membranes can easily be detected.

Publication types

  • Comparative Study

MeSH terms

  • Adult
  • Aged
  • Diabetic Retinopathy / complications
  • Diabetic Retinopathy / diagnostic imaging*
  • Diabetic Retinopathy / surgery
  • Epiretinal Membrane / diagnostic imaging
  • Epiretinal Membrane / etiology
  • Epiretinal Membrane / surgery
  • Humans
  • Macula Lutea / diagnostic imaging
  • Macula Lutea / surgery
  • Middle Aged
  • Reproducibility of Results
  • Retinal Detachment / diagnostic imaging
  • Retinal Detachment / etiology
  • Retinal Detachment / surgery
  • Ultrasonography
  • Video Recording
  • Vitrectomy*
  • Vitreous Body / diagnostic imaging
  • Vitreous Body / surgery